Bosch rexroth Nexo Manual page 191

Cordless wi-fi nutrunner
Hide thumbs Also See for rexroth Nexo:
Table of Contents

Advertisement

3 608 870 A47
ID code source
Under ID code source, the settings defined in the start step under ID code source are displayed.
ID input options
Table 9–17:
Element
Source selection ID input
Choose target for ID input
Masking: ID code /
Masking: ID assignment
Tool display text
Timeout options
Table 9–18:
Element
Timeout
Error message
Nexo cordless Wi-Fi nutrunner | 3 608 870 A47/2019-10
ID input step dialog - ID input options panel
Description
Use this selection to set the source of the ID input of this step.
– Open Protocol
The ID code made available via Open Protocol is used.
– Scanner (only for nutrunners with integrated barcode scanners)
The scanned valid barcode is used.
This provides the following settings for the treatment if the ID input:
– ID code
The ID input is used to create an ID code.
– ID assignment
The ID input is used to select a program or job
using the ID assignment table.
When using this option in the Automatic operating mode, the PLC
signals JobEn, JobStart and Job0-7 must not be applied in the PLC
assignment table.
– ID code + ID assignment
The ID input is used to create an ID code and to select a program or job
using the ID assignment table.
When using this option in the Automatic operating mode, the PLC
signals JobEn, JobStart and Job0-7 must not be applied in the PLC
assignment table.
Depending on the selection made in Target selection ID input, Masking: ID
code and/or Masking: ID assignment is displayed.
Selects where the ID input and the ID code are used. Enter numbers and/or
ranges separated by semicolon. Masking counts up from 1.
Example:
Read-in bar code: N25E9XO12345
Masking: 1;4;6-11
ID code part: NEXO1234
You can save a text for all steps. The text will be displayed on the tool display.
ID input step dialog - timeout options panel
Description
Enter the maximum time when an event, e.g. a successful barcode scan, has
to take place. If no event occurs in this time, the step is terminated.
Enter an error message that will be displayed on the nutrunner display after
the timeout.