Selecting Banks - Omron ZJ-SD Series User Manual

Smart electrostatic sensor
Table of Contents

Advertisement

Section 5

Selecting Banks

Selecting Banks
Up to four setting patterns can be stored in the ZJ-SD, and a set of these patterns is called a
"bank."
• Four banks can be selected.
• Banks are switched by external input leads or the amplifier (bank switching in the FUN mode
[BANK]).
• Switching by external input leads is possible only in the RUN mode.
• Measurement stops during bank switching. Measurement is resumed after the setting data in the
banks is loaded to RAM and setting processing ends.
Bank is switched by [External input lead] or in FUN mode [BANK].
BANK 0
Setting data
■ Procedure for switching banks from an external input lead
The following describes the procedure for switching banks using external input leads (8), (9), (10) and (11) in
the RUN mode.
Switching how input leads are to be used
1.
Turn the pink (8) Bank shift input ON.
The functions of input leads (9), (10) and (11) change as follows:
Orange (9) Zero reset input → Execution of bank switching
Purple (10) Timing input → Bank selection 1
Red (11) Reset input → Bank selection 2
Turn pink (8) Bank shift input OFF when not switching banks.
ZJ-SD
88
User's Manual
BANK 1
Switching
Switching
Setting data
Switching
BANK 2
BANK 3
Switching
Setting data
Setting data
Brown
(1) 24 VDC power
Blue
(2) GND
White
(3) OPE1 judgment output
Green
(4) OPE2 judgment output
Gray
(5) OPE3 judgment output
Black
(6) Linear output
Shield
(7) Linear GND
Pink
(8) Bank shift input
Orange
(9) Zero reset input
Purple
(10) Timing input
Red
(11) Reset input