Section 5
Using the Hold Functions
Setting the Trigger for Measurement in the Hold Mode
Use the UP and DOWN keys to select the desired measurement start conditions.
Selection
TIMNG
(Timing input)
(default)
DIST
(distance trigger)
Selecting the trigger type
1.
Use the LEFT and RIGHT keys to display
[H-TRG] on the main display.
H-TRG is not displayed if the hold condition is set to
[OFF].
2.
Press the UP or DOWN key.
The sub-display flashes.
ZJ-SD
56
User's Manual
Enter the trigger for the start of sampling by using the timing input lead. The
duration that the timing signal from the timing input lead is ON is the sampling
period.
ON
Timing input
OFF
When a delay time is set, the input OFF timing and the end of the
sampling period are not synchronous. Sampling ends after the specified
sampling period has elapsed.
The duration that the displacement sensor detects the specified distance is the
sampling period.
This option can be selected only when a displacement sensor is used.
(Example: When trigger direction = UP)
Trigger direction: UP
Trigger level
Displacement sensor
measured value
Specify the trigger direction, self-trigger level and self-trigger hysteresis
width.
Details
Sampling period
Sampling period
Sampling period