Omron ZJ-SD Series User Manual page 120

Smart electrostatic sensor
Table of Contents

Advertisement

Section 6
Comparing Measured Values (Differentiation Function)
Moving to DIFF
3.
Press the UP or DOWN key.
The sub-display flashes.
4.
Use the UP and DOWN keys to display [SET]
or [ALL].
5.
Press the ENT key.
6.
Use the LEFT and RIGHT keys to display
[DIFF] on the main display.
Moving to the differentiation cycle
7.
Press the UP or DOWN key.
The sub-display flashes.
8.
Use the UP and DOWN keys to display [ON].
9.
Press the ENT key to confirm the setting.
Settings for the differentiation cycle can now be made.