Linear Output
Correcting Linear Output Values
Discrepancies may occur between the linear output current (or voltage) values set on
the Amplifier Unit and the actual current (or voltage) values measured due to the
conditions for the connected external device or other factors. The linear output
correction function can be used to correct this discrepancy.
Output values are corrected by entering the correction value for the current (or voltage)
values of any two points.
Set the monitor focus function and select either current or voltage output beforehand.
This section uses current output as an example. Change the values in this example for
voltage output as necessary.
1.
Connect the linear output to an external ammeter.
Moving to the FUN mode and SPCL
2.
Turn ON the Amplifier Unit and move the
mode switch to FUN.
3.
Use the LEFT and RIGHT keys to display
[SPCL] on the main display.
Moving to L-ADJ
4.
Press the UP or DOWN key.
The sub-display flashes.
5.
Use the UP and DOWN keys to display [SET]
or [ALL].