Moving to FUN Mode and DIST
1.
Set the mode switch to FUN.
2.
Use the LEFT and RIGHT keys to display
[DIST] on the main display.
Setting the Distance Measurement Mode
3.
Press the UP or DOWN key.
The sub-display flashes.
4.
Select the distance correction method.
5.
Press the ENT key to confirm the settings.
This sets the selected mode.
Setting the sensor distance value (when [USER] or [AUTO] is selected in the distance measurement mode)
6.
Use the LEFT and RIGHT keys to display
[S-DIS] on the main display.
In the case of [AUTO]/[FIX]: The distance values currently
recognized by the static electric sensor are displayed.
In the FIX mode, the sensor distance values
need not be entered.
7.
Press the UP or DOWN key.
The leftmost digit of the sub-display flashes.
8.
Measure the sensor distance value.
9.
Press the ENT key to confirm the settings.
This registers the specified distance.
Setting the Installation Distance
Moves from one digit
to another.
Changes the numeric value.