Omron ZJ-SD Series User Manual page 115

Smart electrostatic sensor
Table of Contents

Advertisement

10.
Use the LEFT and RIGHT keys to change the
decimal point position, if necessary.
11.
Press the ENT key to confirm the setting.
The inverted display settings appear on the sub-display.
Selecting inverted display
12.
Use the UP and DOWN keys to select the
inverted display function.
Selection
D-FWD
Not inverted
The measured value displayed on the
Amplifier Unit increases as the charge of the
workpiece increases.
D-INV
Inverted
The measured value displayed on the
Amplifier Unit decreases as the charge of the
workpiece increases.
13.
Press the ENT key to confirm the setting.
The sub-display indicates "P2SCL".
14.
Press the ENT key.
Details
Section 6
Changing Display Scales
User's Manual
ZJ-SD
101