Omron ZJ-SD Series User Manual page 97

Smart electrostatic sensor
Table of Contents

Advertisement

Moving to the FUN mode and OUTPT
1.
Set the mode switch to FUN.
2.
Use the LEFT and RIGHT keys to display
[SPCL] on the main display.
3.
Press the UP or DOWN key.
The sub-display flashes.
4.
Use the UP and DOWN keys to display [ETC]
or [ALL].
5.
Press the ENT key.
6.
Use the LEFT and RIGHT keys to display
[OUTPT] on the main display.
Selecting the output type
7.
Press the UP or DOWN key.
The sub-display flashes.
8.
Select the output type.
When a warning level is set, select [WARN], and when
not set, select [STAND].
9.
Press the ENT key to confirm the setting.
This registers the setting.
When [WARN] is selected, set the warning level.
Setting the Warning Level (Output type)
Section 5
ZJ-SD
83
User's Manual