Omron ZJ-SD Series User Manual page 62

Smart electrostatic sensor
Table of Contents

Advertisement

Section 4
Measuring Sheet Workpieces
Setting the Sensor Distance Value
Set the distance values of the workpiece and sensor.
In the USER mode, the distance values are fixed by the specified distance.
In the AUTO mode, the positional relationship between the displacement sensor and
the ZJ-SD sensor is registered using preset distances so that distance correction
using the displacement sensor is possible.
In the FIX mode, the sensor distance values need not be entered.
Setting the sensor distance value (when [USER] or [AUTO] is selected in the distance
measurement mode) p.43
Setting Measurement Timing
Use the bottom hold function to hold the minimum value (bottom) during the sampling
period.
If the timing cannot be entered from the device, select [DIST] at "Hold trigger" so that sampling can
be performed matched to the distance values measured by the distance sensor.
v
Refer to "Section 5 DETAILED SETTINGS" for details on settings.
Using the Hold Functions p.53
ZJ-SD
48
User's Manual
Sampling
Measured value
The bottom value is held.
t