Omron ZJ-SD Series User Manual page 91

Smart electrostatic sensor
Table of Contents

Advertisement

Output Settings for Non-measurement
The linear output method for when a reset is input can be set.
Selection
KEEP
The measured value immediately before measurement is stopped is held and output.
(default)
CLAMP
All outputs turn OFF.
• In the case of hold measurement
Even if [KEEP] is set, the output before the first hold value is obtained is the same as [CLAMP].
• Even in FUN mode, the outputs are made according to the non-measurement settings.
Moving to the FUN mode and SPCL
1.
Set the mode switch to FUN.
2.
Use the LEFT and RIGHT keys to display
[SPCL] on the main display.
Moving to RESET
3.
Press the UP or DOWN key.
The sub-display flashes.
4.
Use the UP and DOWN keys to display [ETC]
or [ALL].
5.
Press the ENT key.
Judgment outputs
The set CLAMP value is output.
The following options are available:
Outputs
Linear output
• At current output: 3 to 21 mA or maximum
(approx. 23 mA)
• At voltage output: -5 to 5 V or maximum (approx.
5.5 V)
Section 5
Linear Output
ZJ-SD
77
User's Manual

Advertisement

Table of Contents
loading

Table of Contents