Section 2
Basic Configuration
■ When a personal computer (and Amplifier Unit) are included in the
basic configuration
The [Reference destination setting] can be set in the Static Electricity Smart Monitor.
Example 1)
Example 2)
ZJ-SD
8
User's Manual
1ch: ultrasonic sensor
2ch: static electricity sensor
3ch: static electricity sensor
4ch: static electricity sensor
0ch: Interface Unit
1ch: ultrasonic sensor
2ch: static electricity sensor
3ch: ultrasonic sensor
4ch: static electricity sensor
0ch: Interface Unit
(When [Reference destination
setting] is set to [CH1]),
the static electricity sensor on
2ch to 4ch can perform
correction using the data of
the ultrasonic sensor on 1ch.
*(When [Reference
destination setting] is set to
[Next CH]),
the static electricity sensor on
2ch and 4ch can perform
correction using the data of
the ultrasonic sensors on 1ch
and 3ch, respectively.
*4ch cannot reference 1ch
and 2ch cannot reference
3ch.