Machine transportation after setup > Procedure for the main unit transportation (Truck transportation)
41
Remove 2 screws.
42
Hold and remove the protective cap [A] in the direction of arrow.
Please make sure not to touch the print head by the protective cap.
IMPORTANT
In case of turning power on without removing the cap unit, the belt of the image conveying unit, caps in the treatment unit
and the wipe section mights get broken.
C2120: Treatment cap HP sensor error (See
NOTE
Clean the cap unit with Alfa wipes and deionized water, and keep it for other transportation in future.
43
Push the treatment unit [A] in the inside of the main unit.
44
Please make sure to check the position of the screw [B] located at bottom side of the
treatment unit [A].
[A]
page 5-3
for the corrective action of service call)
[B]
6-44