The main unit setup procedure > Remove the transportation spacers
7
Re-install the cap unit [A] until feeling a click.
Confirm if the center of the shaft [B] matches with center of position [C].
IMPORTANT
If forgetting to remove the cap plate, C2100 will occur.
C2100: Treatment carriage HP sensor error (See
8
Remove the treatment front plate [A]. (Screw x2)
9
Remove the treatment rear plate [A]. (Screw x2)
[A]
page 5-1
[A]
2-17
for the corrective action of service call)