DEFINITY
Communications System
DEFINITY High Speed Link
User´s Guide
Appendix D: Applications and Switch Administration
ENHANCED MODE - PROCEDURE:
MULTIAPPEARANCE TERMINAL AND DATA MODULE TRANSLATION
TERMINAL EQUIPMENT LOCATION
1.
Module: [--]
2.
Cabinet: [-]
3.
Carrier: [-]
4.
Slot: [--]
5.
Circuit: [--]
TERMINAL OR DATA MODULE TYPE
6.
Terminal Type: [1]
7.
Option: [0]
PHYSICAL TYPE
8.
Data: [2]
9.
Display: [-]
PREFERENCE
10.
Origination: [2]
11.
Termination: [0]
Generic 2 HSL Station Administration
PROC 051 Word 1 (Screen D-5) is used to define a data
module. The fields must be populated in the following
manner:
Field 6 (Terminal Type): 1. To indicate a PDM (the HSL is
aliased as a PDM).
Field 7 (Option): 0. To indicate data.
Field 8 (Data): 2. Because the PDM is not an available
choice, the 7400 should be entered.
Field 10 (Origination): 2. To originate on prime line.
Field 11 (Termination): 0. To indicate no preference on
termination assignment.
Field 13 (Keybd Dialing): 1. To allow the HSL to
dial/originate calls. In this example this is done through
the RS-366 interface.
PROC 052 Word 1 is used to define the line appearance and
match the HSL extensions to the equipment location. The
fields must be populated in the following manner:
Field 8 (Extension number): 4000, 4001. This should be
populated with the HSL extension as defined in PROC 000.
Field 9 (Line Appearance): 1. There is only one line
appearance with the HSL.
Field 10 (Line Type): 1. To indicate prime line answering.
051, WORD:1
12.
Lock/Unlock Available: [-]
13.
Keyboard Dialing: [1]
14.
LWC Global Retrieval: [-]
15.
Terminal Alarming: [-]
16.
BRI TEI: [---]
17.
ISDN Advantage: [-]
SCREEN D-5
Page D-17