Avaya 6424D+M User Manual page 43

Avaya 6424d+m: users guide
Hide thumbs Also See for 6424D+M:
Table of Contents

Advertisement

DEFINITY
Communications System
DEFINITY High Speed Link
User´s Guide
The POWER/TEST lamp winks during the test and stops
winking when the test is completed.
Notes:
If you attempt to start a local loopback test when a
switch test is in progress, the HSL displays
DENIED:
TEST IN PROGRESS
LOCAL LOOPBACK?
If you attempt to start a local loopback test when
another test (other than a switch activated test) is in
progress, the HSL displays
DENIED:
TEST IN PROGRESS
LOCAL LOOPBACK?
To end the local loopback test, press ENTER/YES while the
3
HSL displays END LOCAL LOOP? The HSL displays
TEST ENDED
LOCAL LOOPBACK?
Note:
If you attempt to end a local loopback test started by
the switch, the HSL displays
DENIED:
ACTIVATED TEST
END LOCAL LOOP?
If you end a local loopback test from the front panel
when the V.35 Local Loopback input lead is ON, the
test automatically restarts and the HSL displays
TEST ENDED
END LOCAL LOOP?
Press ENTER/YES to repeat the test, or NEXT/NO to display
4
the next test.
Note:
Press NEXT/NO and BACK simultaneously to return
to the HOME screen.
Chapter 3: Using the Front Panel
SWITCH