Test-Reset; Procedure: Selecting A Test; Data Loopback Test - Avaya 6424D+M User Manual

Avaya 6424d+m: users guide
Hide thumbs Also See for 6424D+M:
Table of Contents

Advertisement

Chapter 3: Using the Front Panel
Page 3-10

Test-Reset

The Test-Reset menu allows you to control the unit's test features
and to reset the options to the default settings.
The Test-Reset screens are listed below.
TABLE 3-5
Test-Reset Screens
DATA LOOPBACK?
SELF-TEST?
LOCAL LOOPBACK?
REMOTE LOOPBACK?
REMOTE LOOP/ST?
RESET OPTIONS?
EXIT->TESTS?

Procedure: Selecting a Test

Use the procedure below to select a test:
From the HOME screen, press NEXT/NO or BACK until the
1
HSL displays TEST-RESET? Once displayed, press
ENTER/YES .
Press NEXT/NO or BACK to step through the available tests.
2
Note:
Except for self-test, only one test may be activated at a
time, and a test must end before another can be activated.
Procedures for running each test follow. For additional
information refer to Chapter 6, ''Test Descriptions.''

Data Loopback Test

The data loopback test can be initiated by the front panel interface,
a command from the switch, a remote data endpoint, or a network
test center.
You should initiate this test when data errors are detected and
remote testing of the HSL and network is desired. You must be on
a data call to run a data loopback test.
The following procedure contains step-by-step instructions for
initiating a data loopback test from the front panel interface. Refer
to the Data Loopback Test section in Chapter 6, ''Test
Descriptions'' for details of this test.
DEFINITY
or
END DATA LOOP?
or
END LOCAL LOOP?
or
END REMOTE LOOP?
or
END REM LOOP/ST?
Communications System
DEFINITY High Speed Link
User´s Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents