Error Code Troubleshooting
IOT Option Feeder I/F Failure
Phaser 6500/WorkCentre 6505 Service Manual
An Option Feeder communication failure is detected.
Applicable Error Code
•
004-310
Troubleshooting Reference Table
Applicable Parts
Option Harness Assy (PL3.1.20)
■
MCU Board (SFP PL8.2.13; MFP
■
PL8.3.6)
Optional Feeder Assy (PL12.1.3)
■
Tray Harness Assy (Optional
■
Feeder Harness) (PL12.3.23)
Troubleshooting Procedure
Step Actions and Questions
1
Is the Optional Feeder installed
correctly?
2
Does the error still occur when
printing?
3
Are the connections between the MCU
Board and Option Feeder Board (P/
J27, P/J273, and P/J419) connected
securely?
4
Does the error still occur when
printing?
5
Check the Optional Feeder Harness for
continuity.
Disconnect P/J419 from the Option
Feeder Board and P/J273 from the
Option Harness Assy.
Is each cable of P/J419 <=> P/J273
continuous?
Xerox Internal Use Only
Error Messages and Codes
Wiring and Plug/Jack Map References
"SFP Optional Feeder Plug/Jack
■
Designators" on page 10-5
"Map 5 - SFP Optional Feeder" on
■
page 10-10
"MFP Optional Feeder Plug/Jack
■
Designators" on page 10-14
"Map 10 - MFP Optional Feeder" on
■
page 10-19
Yes
Go to step 3.
Go to step 3.
Go to step 5.
Go to step 5.
Go to step 6.
No
Reseat the
Optional
Feeder, then
go to step 2.
Complete.
Reconnect the
Plugs/Jacks
securely, then
go to step 4.
Complete.
Replace the
Optional
Feeder Harness
(page 8-179).