Calibration
Azimuth calibration with a service profile
1. Click SERVICE > Calibration.
2. Select the service profile in the drop down list Satellite. All profiles with the modem
Service modem are displayed in the list. If there is no profile in the list, you must set
up one, see Service profile for calibration on page 5-10.
3. Click Start in the section Azimuth calibration and wait typically 5 minutes for the
calibration to finish. After finished calibration a message with the result of the
calibration is displayed in the field Result.
5.3.2

Service profile for calibration

If you do not want to use the automatic azimuth calibration or if you want to enter the
satellite parameters directly on the calibration page, use this calibration method. To
prepare for calibration you can set up a service profile for calibration.
To setup a service profile do as follows:
1. Connect a PC to LAN connector 3 (Service port, standard Ethernet) of the ACU or to
the front LAN connector of the ACU.
2. Open an Internet browser and enter the IP address of the ACU (Default:
http://192.168.0.1).
3. Select SETTINGS > Satellite profiles > New entry. Enter the name of the satellite
profile for calibration (a name of your own choice, e.g. IOR Inmarsat GX).
4. Select the VSAT modem profile Service & Calibration from the drop-down list.
5. Enter the data for the satellite that you want to use as a calibration reference. Note the
following calibration requirements:
Elevation angle: 5 – 70 degrees.
Not allowed for calibration: Inclined orbit.
5-10
Figure 5-8: Satellite profile for calibration