Separate Ground Cable; To Construct A Ground Cable - Furuno FV-110GX Operator's Manual

Gx terminal
Table of Contents

Advertisement

A.6

Separate ground cable

A.6.1

To construct a ground cable

When dealing with electrical installations in a marine environment, all wiring must be
done with double insulated, tinned strands, high quality and if exposed also UV resistant
cables. This shall also apply to the separate ground cable mentioned in the previous
paragraphs.
The ground cable is constructed using an appropriate cable with a cross section area of at
least 6 mm
illustration below. The crimp terminals must be a marine approved type e.g. the DuraSeal
series from Raychem.
Figure A-6: Separate ground cable
2
(AWG10) and terminated with insulated ring crimp terminals, see the
Antenna:
M12 Insulated Ring Terminal
(Raychem, DuraSeal Series)
Terminal:
Appropriate size
Insulated Ring Terminal
(Raychem, DuraSeal Series)
Separate ground cable
A-9