Installation Check List: Functional Test In Harbor - Furuno FV-110GX Operator's Manual

Gx terminal
Table of Contents

Advertisement

6.3

Installation check list: Functional test in harbor

Step
1.
Check that the antenna is
tracking the satellite
2.
Check that the GMU is in lock
and BUC TX on.
3.
Connect a user PC LAN (not the
service PC) to the Internet LAN
connector 2 of the ACU.
4.
Open a DOS window and type:
ping 4.2.2.2.
5.
Open a web browser and browse
to e.g. www.google.com.
6.
If step 4 is successful and step 5
is not then it seems that the DNS
is not configured correctly.
Task
Table 6-3: Installation check list: Functional test in harbour
Installation check list: Functional test in harbor
Further information
The logon LED in the ACU display
must be steady green and the display
shows: TRACKING.
In the web interface and in the
Control Panel check:
DASHBOARD:
System status: Tracking (see
Connecting to the web interface on
page 5-1).
In the web interface check:
DASHBOARD, RX locked status
must show Locked.
The ACU display must show
MDM:NETOK
The GMU needs no separate setup.
See To connect the ADU, ACU and
GMU on page 2-29.
Check that you get a response.
Check that the web page is
downloaded.
See the page SETTINGS > Network
and check the DNS setup (see To
configure the LAN network on page 5-
23.
Done
6-3