Alternative ground for fibre glass hulls

A.5
Alternative ground for fibre glass hulls
A.5.1

To ground the ACU

To ground the ACU do as follows:
1. Preferably ground the ACU with the short ADU cable and a grounding kit (available
from FURUNO).
2. Ground the ACU at its grounding stud in order to ensure a proper grounding if the
short ADU cable is disconnected.
3. You must establish the ground connection at a dedicated RF ground (either capacitive
or electrical coupled).
Important
A.5.2

To ground the ADU

To ground the ADU do as follows:
1. If the mounting base of the ADU is electrically connected to any other ground
potential than the ACU (e.g. Lightning Ground), you must isolate the ADU at its
mounting bolts with shoulder bushings and washers - see section A.6.3.
2. However, you must establish a ground connection via one of the mounting bolts with a
separate ground cable.
3. You must route the ground cable in parallel and in close proximity to the shielded coax
cable hence connecting the ADU to the ACU Grounding kit. Use a heavy gauge wire
with tinned strands (min. 6 mm
A-8
Bear in mind that the ADU ground connection is to be
made at the same electrical ground potential as the
ACU (see To ground the ADU).
Figure A-5: Alternative grounding for fibreglass hulls
2
) for this purpose.