Status Signalling With Leds And Status Messages; Leds Of The Adu Modules - Furuno FV-110GX Operator's Manual

Gx terminal
Table of Contents

Advertisement

7.4

Status signalling with LEDs and status messages

Built-In Test Equipment
The ADU and the ACU have a Built-In Test Equipment (BITE) function in order to make
fault diagnostics easy during service and installation. The BITE test is performed during:
• Power On Self Test (POST), which is automatically performed each time the system is
powered on.
• Person Activated Self Test (PAST), which is initiated by starting a self test in the web
interface HELPDESK > Self test.
For details on error messages after a POST or a self test see Event list on page 7-4.
Means of signalling
The FV-110GX provides various methods for signalling the system status. LEDs on the
front panel of the ACU are used to signal:
• Power on/off
• Logon
• Fail/Pass
The built-in web interface of the ACU shows any events (BITE error codes) with a short
message describing each error. This is also displayed in the ACU.
In an error situation, one of the following system status messages may be shown:
• ACU POST error
• Antenna POST error
• SAFE MODE (plus information about the specific error, see System messages on
page B-1).
7.4.1

LEDs of the ADU modules

Each ADU module has a Power and a Service LED.
LED
Power
Service Steady green
For a list of modules see Removal and replacement of ADU modules on page 7-17.
Behaviour
Steady green
Power supply OK
Off
No power
Module ok, application
running.
Flashing green
Waiting for upload
Flashing red/green Uploading software
Steady red
Module error or loading error
Table 7-1: LEDs of the ADU modules
Status signalling with LEDs and status messages
Description
7-15

Advertisement

Table of Contents
loading