2.3.3

To ground the ADU

The ADU must be grounded using the mounting bolts.
To ground the ADU do as follows:
1. Clean the metal underneath the head of at least one bolt of insulating protective
coating and use a serrated washer to obtain a good ground connection
2. Tighten the bolts. Use stainless steel bolts and washers.
3. Seal the area suitably to avoid corrosion of the grounding point (recommended).
For optimum grounding connect the ground wire to the bolt marked in the figure
below.
If the ADU cannot or should not be electrically connected directly to the mounting
surface, you can use a separate grounding cable to make the connection between the ADU
and the common ground to which the ACU is also connected. If grounding to the ship
ground is impossible, for example if you have a fibre glass hull, see Alternative ground
for fibre glass hulls on page A-8.
For further information on grounding and RF protection see the appendix Ground and RF
protection on page A-1.
247.5
ø350
248
R326
Current antenna
Figure 2-23: ADU, bolt for optimum grounding
Installation of the ADU
72.5
247.5
N-Connector
164.5
New antenna
2-25