Mast Foundation And Height - Furuno FV-110GX Operator's Manual

Gx terminal
Table of Contents

Advertisement

Site preparation
2.2.6

Mast foundation and height

The ADU mast must be designed to carry the weight of the ADU (126 kg), plus the
weight of the mast flange. The mast must also be able to withstand on-board vibrations
and wind speeds up to 110 knots on the radome, even in icing conditions.
Follow the guidelines in the sections:
• ADU mast flange
• Mast length and diameter
ADU mast flange
To prepare the mast flange do as follows:
1. Fit the top of the ADU mast with a flange with clearance holes matching the bushings
in the radome and with minimum 4 gusset plates. No center hole is necessary in the
flange.
• Flange thickness: Minimum 15 mm.
• 4 gusset plates: Minimum 15 mm thick, must be placed close to the holes in the
mounting plate and evenly distributed.
2. Make sure that the recommended flatness on the mast mount plateau is below 3,0 mm.
Figure 2-7: ADU mast flange, recommended flatness on the mast mount
2-8
Gusset plates
(15 mm thick)
Max. 440 mm
Figure 2-6: ADU mast flange, top and side view
plateau
15 mm