To get support
7.1.3
Reset to factory default - GMU
To reset the GMU to factory default, do as follows:
1. From the left navigation pane, select SERVICE > Modem.
2. In the drop-down box select one of the three options:
• Level 0 – Power cycle of the GMU
• Diagnostic Test Mode – Only connection to the GMU is the serial RS-232
interface, all other connections are shut down.
• Default Factory Configuration – Do not select this! The GMU stops working. New
files must be loaded into the GMU. Contact your service provider.
3. To power cycle the GMU push the power switch.
7.1.4
Line up procedure
The FV-110GX has a line-up utility for testing the modem connection.
Note
The FV-110GX has been tested at the factory and online on a live satellite link. You can
also make a line up and adjust the azimuth and elevation manually. Do as follows:
1. Open your Internet browser and enter the IP address of the ACU. The default IP
address is http://192.168.0.1.
2. Create a modem profile and a satellite profile using the previously created modem
profile (See Service profile for calibration on page 5-10).
7-6
CAUTION! The system becomes inoperable if you select Default Factory
Configuration in the drop down list on the page SERVICE > Modem.
Figure 7-3: Web interface: SERVICE > Modem, Factory default
The ship must not move during the line-up procedure.