List Of Adu Events - Furuno FV-110GX Operator's Manual

Gx terminal
Table of Contents

Advertisement

List of ADU events

B.2
List of ADU events
Error
Unit
code (ID)
0A001-0
Antenna ERROR
0A002-0
Antenna ERROR
0A003-0
Antenna ERROR
0A004-0
Antenna ERROR
0A005-0
Antenna ERROR
0A006-0
Antenna ERROR
0A007-0
Antenna ERROR
0A008-0
Antenna ERROR
0A00A-0 Antenna ERROR
0A014-0
Antenna ERROR
0A015-0
Antenna ERROR
0A016-0
Antenna ERROR
0A017-0
Antenna ERROR
B-2
Severity
Description
Production data
XIM internal
XIM external
XIM I/X match
Antenna type
PCM FPGA
load
XIM FPGA load The VIM/TIM FPGA cannot be initialised and
XIM production Production/calibration data stored in the
GNSS
initialisation
AMB device
discovery
Azi DDM ABS
device
Xel DDM ABS
device
Ele DDM ABS
device
Table B-1: ADU event messages
Explanation
Production data is invalid.
Antenna configuration data stored in the PCM
module is invalid.
Antenna configuration data stored in the
VIM/TIM module is invalid.
Antenna configuration data stored in the PCM
module does not match the configuration data
stored in the VIM/TIM module.
The configured antenna type is not supported
or unknown.
The PCM FPGA cannot be initialised and
loaded correctly.
loaded correctly.
VIM/TIM module is invalid.
The GNSS device cannot be initialised. Check
cable and GNSS device.
Missing one or more of the following devices:
ISM, DDM and PMM. Check cables.
Cannot initialise the azimuth DDM. Info:
0x00000000: Device not found (possible
cabling problem)
0x0000bbaa: Device internal error (replace
device) aa=status, bb=state.
Cannot initialise the cross-elevation DDM.
Info: See 0A015-0.
Cannot initialise the elevation DDM. Info: See
0A015-0.

Advertisement

Table of Contents
loading

Table of Contents