On the PC:
34. Insert the SD Card into the card reader.
35. Run the HSCM.exe program (verify interface resembles Figure 2-30).
36. Choose CESSNA SEP in the Select Aircraft field.
37. Standby Battery Ammeter is the only selection available in the Select Channel field.
38. Enter the value of READING #2 in the Input Offset Error in Amps field.
39. Verify the drive letter of the SD card reader is selected in the Select SD Card Drive Letter field.
40. Press the Create Correcting Config File button.
41. Press OK to acknowledge the pop-up box.
42. Verify the pop-up box annunciates "Cessna SEP file written to drive" and press OK to acknowledge.
43. Press the Close button.
44. Remove the SD card from the card reader.
In the Aircraft:
45. Insert the SD card into the upper card slot of the PFD.
46. Power up MFD1 and PFD1 in Configuration mode:
A. MASTER Switch (BAT) – On
B. AVIONICS Switch (BUS 1 and BUS 2) – On
Page 2-70
Rev. L
Figure 2-30. HSCM Offset Tool User Interface
G1000 Nav III Line Maintenance Manual
190-00352-00