:TRIGger:CAN:SOURce

Command Syntax
:TRIGger:CAN:SOURce <source>
<source> ::= {CHANnel<n> | EXTernal} for the DSO models
<source> ::= {CHANnel<n> | DIGital0,..,DIGital15} for the MSO models
<n> ::= {1 | 2 | 3 | 4} for the four channel oscilloscope models
<n> ::= {1 | 2} for the two channel oscilloscope models
The :TRIGger:CAN:SOURce command sets the source for the CAN signal.
The source setting is only valid when :TRIGger:CAN:TRIGger is set to SOF
(start of frame).
Query Syntax
:TRIGger:CAN:SOURce?
The :TRIGger:CAN:SOURce? query returns the current source for the CAN
signal.
Return Format
<source><NL>