PVC Tests

PVC tests can be run on a requested DLCI for a selected interface. The
FrameSaver unit must be operating in frame relay mode.
T
T
Loopback, and send/monitor pattern tests are available for each interface on the
selected DLCI. FrameSaver devices should be at each end of the circuit. If a
PVC Loopback is started at one end of the circuit, the other end can send and
monitor pattern tests.
The example below shows a PVC Test screen for a FrameSaver unit with the
multiplexed DLCI 550 selected. If a standard DLCI was selected, (Disruptive),
rather than (Non-Disruptive), would be displayed after Test. Also, the
Connectivity test would not appear.
PVC Tests Screen Example
9123-A2-GB20-20
When PVC tests are on a multiplexed DLCI between FrameSaver devices,
they are nondisruptive to data, so user data can continue to be sent during a
test.
If the device at one end of the circuit is not a FrameSaver device, PVC tests
are on a standard DLCI and are disruptive to data. Also, the Connectivity test
would not appear.
main/test/network_pvc
Device Name: Node A
DLCI Number: 550
Test (Non-Disruptive)
PVC Loopback:
Send Pattern:
Monitor Pattern:
Connectivity:
--------------------------------------------------------------------------------
Ctrl-a to access these functions, ESC for previous menu
NOTE:
Errors encountered during these tests may be caused by mismatched CIRs in
the two FrameSaver units. If errors are detected, verify the CIR configuration
and retest.
August 2001
NETWORK PVC TESTS
Command
Status
Result
Start
Inactive
0:00:00
Start
Inactive
0:00:00
Start
Inactive
0:00:00
Sequence Errors
Data Errors
Start
Inactive
RndTrip Time (ms)
6. Troubleshooting
9123-C-SLV
3/26/2000 23:32
99999+
99999+
99999