5. Operation and Maintenance
Table 5-7.
5-16
Health and Status Messages (3 of 3)
Message
SLV Timeout, DLCI nnnn ,
1, 2, 3
frame relay link
Two Level-1 Users Accessing
Device
Time Slot Discovery in Progress,
Network 1
Yellow at Network 1
1
nnnn indicates a DLCI number of 16 through 1007.
2
frame relay link is one of the following:
– Net1-FR1. The frame relay link specified for the network interface, Network 1.
– Port-1. The frame relay link associated with the user data port.
3
Does not apply to a TS Management Link DLCI.
August 2001
What It Indicates
An excessive number of SLV communication
responses from the remote FrameSaver SLV unit
have been missed on the specified multiplexed
DLCI; the DLCI is not suitable for user data.
When a hardware bypass capable device has been
detected at the other end of the PVC and this
condition occurs, only user data for EDLICI 0 will be
transmitted while this condition exists.
Two Level 1 users are already using the menu-
driven user interface; only two sessions can be
active at one time.
Time slot discovery is currently taking place to
determine the time slots that will be used for frame
relay traffic on the network interface.
This message only appears when the Time Slot
Discovery option is enabled ( Main Menu →
Configuration → Time Slot Assignment → Frame
Relay Network Assignments) and an LMI failure is
detected on the network interface's frame relay link.
A yellow alarm signal is received on the network
interface. Possible reasons include:
T
Network cable problem.
T
T1 facility problem.
9123-A2-GB20-20