To see how the FrameSaver unit's menu structure differs based upon the Service
Type setting, see
The Service Type setting can be changed on demand. When Service Type is
changed, the Changing "Service Type" will effect overall device
operation. Are You Sure? prompt appears. If you select No, no changes are
made. If you select Yes, the edit copy of the system options is updated to reflect
the changed mode. A Save is required to apply option updates to the current
configuration.
See the
and installation procedures. See
for its document number.
9123-A2-GB20-20
If the selection is . . .
The unit is configured to operate in . . .
Leased Line
Leased-line mode, for connection to a standard leased-line
service. This mode provides a simple and straight-forward
screen to guide the installer during initial installation, and to set
up remote access to the unit.
When operating in leased-line mode, no frame relay-related
statuses, performance statistics, tests, configuration options, or
control features are available; only physical layer functions are
available.
NOTE: If previously set to Frame Relay, then changed to
Leased Line, all frame relay-related screens and features are
filtered so they are transparent to the user. All frame relay links,
DLCIs. and PVCs are preserved.
In the case of time slots, all Frame Relay Network 1 FrameRly1
time slot assignments are converted to S1Port-1 on the Sync
Data Port Assignments screen.
Frame Relay
Frame Relay-aware mode, for connection to a frame relay
service. This is the default operational mode, and it is used to
(default)
configure the FrameSaver unit in frame relay mode so that frame
relay parameters and SLV functionality can be set up.
When operating in frame relay mode, all frame relay-related
statuses, performance statistics, tests, configuration options, and
control features are available.
NOTE: If previously set to Leased Line, then changed to Frame
Relay, Time Slot Discovery is temporarily suspended until LMI
communication is reestablished, and all frame relay-related
configuration options previously set up are restored, except for
the Sync Data Port Assignments. In this case, all port
assignments set to S1Port-1 are converted to FrameRly1
assignments on the Frame Relay Network 1 Assignment timeslot
assignment screen.
Appendix A, Menu Hierarchy
FrameSaver FLEX 9123 Installation Instructions
August 2001
.
for additional information