6. Troubleshooting
Table 6-1.
6-10
Alarm Conditions (4 of 4)
Alarm Condition
What It Indicates
SLV Timeout,
An excessive number of
DLCI nnnn ,
SLV communication
1,2
frame relay link
responses from the remote
system have been missed
on the specified multiplexed
DLCI and link.
If the frame relay link is
Net1-FR1, the timeout is on
the network FrameRly1
timeslot assignment.
When a hardware bypass-
capable device has been
detected at the other end of
the PVC and this condition
occurs, only user data for
EDLCI 0 will be transmitted
as long as the condition
exists.
Two Level-1 Users
Another user with Level-1
Accessing Device
security access is currently
accessing the unit.
Be aware that actions of the
other user may override
your test commands and
configuration changes.
Yellow at Network 1
A yellow alarm signal is
received on the network
interface.
T
T
1
nnnn indicates a DLCI number of 16 through 1007.
2
frame relay link is one of the following:
– Net1-FR1. The frame relay link specified for the network interface, Network 1.
– Port-1. The frame relay link associated with the user data port.
August 2001
What To Do
Verify that the network LMI is up. If
it is, contact your network service
provider.
Wait until no other Level-1 users
are accessing the unit if testing or
configuration will be performed.
T
Network cable problem.
T
T1 facility problem.
Check that your network cable
is securely attached at both
ends.
Contact your network provider.