6. Troubleshooting
Restoring Communication with a Misconfigured Unit
Misconfiguring the unit could render the menu-driven user interface inaccessible. If
this occurs, connectivity to the unit can be restored via a directly connected
asynchronous terminal.
Procedure
To reset COM port settings:
6-4
1. Configure the asynchronous terminal to operate at 19.2 Kbps, using character
length of 8 bits, with one stop-bit, and no parity. In addition, set Flow Control to
None.
2. Reset the unit, then hold the Enter key down until the System Paused screen
Resetting the Unit and Restoring Communication
appears. (See
for other methods of resetting the unit.)
3. Tab to the desired prompt, and type y (Yes) at one of the prompts.
If selecting . . .
Reset COM Port usage
Reload Factory Defaults
If no selection is made within 30 seconds, or if No (n) is entered, the unit
resets itself and no configuration changes are made.
Once the unit resets itself, connectivity is restored and the Main Menu screen
appears.
August 2001
The following occurs . . .
T
Port Use is set to Terminal so the asynchronous
terminal can be used.
T
Data Rate (Kbps), Character Length, Stop Bits, and
Parity are reset to the factory defaults.
T
Unit resets itself.
T
All configuration and control settings are reset to the
Default Factory Configuration, overwriting the current
configuration.
T
Unit resets itself.
CAUTION: This causes the current configuration to
be destroyed and a self-test to be performed.
on page 6-3
9123-A2-GB20-20