6. Troubleshooting
Table 6-1.
6-8
Alarm Conditions (2 of 4)
Alarm Condition
What It Indicates
Link Down
The specified frame relay
Administratively,
link has been disabled by
2
frame relay link
the unit due to LMI Behavior
conditions or LMI Protocol
on another link is in a failed
state.
This is not an alarm
condition so System
Operational appears, as
well.
LMI Down,
The Local Management
2
frame relay link
Interface is down for the
specified frame relay link.
1
nnnn indicates a DLCI number of 16 through 1007.
2
frame relay link is one of the following:
– Net1-FR1. The frame relay link specified for the network interface, Network 1.
– Port-1. The frame relay link associated with the user data port.
August 2001
What To Do
Verify that the network LMI is up. If
it is, contact your network
provider.
For the network interface:
For the network data port:
T
If LMI was never up, verify that
the LMI Protocol setting
reflects the LMI type being
used.
T
If LMI was never up:
– Verify that the proper time
slots have been configured.
– Verify that the LMI Protocol
setting reflects the LMI type
being used.
T
Verify that Frame Relay
Performance Statistics show
LMI frames being transmitted.
If all of the above have been
verified and the physical link is not
in Alarm, contact your network
provider.
For user data port:
T
Check that the DTE cable is
securely attached at both ends.
T
Verify that Transmit Clock
Source and Invert Transmit
Clock options are properly
configured.
T
Verify that Frame Relay
Performance Statistics show
LMI frames being received. If
no frames are being received:
– Check the attached device.
– Verify that the LMI Protocol
setting reflects the LMI type
being used.
9123-A2-GB20-20