Paradyne FrameSaver FLEX 9123 User Manual page 89

Table of Contents

Advertisement

Table 3-14. SNMP Traps Options (2 of 3)
9123-A2-GB20-20
NMS n IP Address
Possible Settings: 001.000.000.000 – 223.255.255.255, Clear
Default Setting: Clear (000.000.000.000)
Specifies the IP address that identifies the SNMP manager(s) to receive SNMP traps.
Display Conditions – This option appears for each trap manager specified in the
Number of Trap Managers configuration option.
001.000.000.000 – 223.255.255.255 – Adds to or changes the IP address for the trap
manager.
Clear – Fills the NMS IP address with zeros.
Initial Route Destination
Possible Settings: AutoRoute, Ethernet, COM, PVCname
Default Setting: AutoRoute
Specifies the initial route used to reach the specified Trap Manager. When proprietary RIP
is active, only one unit in the network needs to specify an interface or management link as
the initial destination. All other units can use the default setting.
Display Conditions – This option appears for each trap manager specified in the
Number of Trap Managers configuration option.
AutoRoute – Uses proprietary RIP from other FrameSaver devices to learn the route for
sending traps to the specified Trap Manager, or the Default IP Destination when no route
is available in the routing table (see
Ethernet – Uses the Ethernet port. Only appears when the Ethernet port's Interface
Status option is enabled (see
COM – Uses the COM port. Only available when Port Use is set to Net Link (see
Table 3-16, Communication Port
PVCname – Uses the defined management linkname (the name given the Management
PVC). Only appears when at least one Management PVC is defined for the node.
General Traps
Possible Settings: Disable, Warm, AuthFail, Both
Default Setting: Both
Determines whether SNMP trap messages for warmStart and/or authenticationFailure
events are sent to the currently configured trap manager(s).
Disable – Does not send trap messages for these events.
Warm – Sends trap messages for warmStart events only.
AuthFail – Sends trap messages for authenticationFailure events only.
Both – Sends trap messages for both warmStart and authenticationFailure events.
Enterprise Specific Traps
Possible Settings: Enable, Disable
Default Setting: Enable
Determines whether trap messages for enterpriseSpecific events are sent to the currently
configured trap manager(s).
Enable – Sends trap messages for enterpriseSpecific events.
Disable – Does not send trap messages for enterpriseSpecific events.
August 2001
Table 3-9, Node IP
Options).
Table 3-15, Ethernet Port
Options).
Options).
3. Configuration
3-55

Advertisement

Table of Contents
loading