Table 3-8.
9123-A2-GB20-20
PVC Connection Options (2 of 2)
Destination Link
Possible Settings: Net1-FR1
Default Setting: Initially blank; no default.
Specifies the frame relay interface used as the destination link; the to end of a from-to
link. The only valid settings for this configuration option are frame relay interfaces that
have at least one DLCI or EDLCI defined which are not part of a PVC connection or
management link. For example, if the network interface has no DLCIs defined, Net1-FR1
would not appear as a valid setting.
Net1-FR1 – Specifies the Network interface as the destination link.
Destination DLCI
Possible Settings: 16 – 1007
Default Setting: Initially blank; no default.
Specifies the destination DLCI for a frame relay interface. The DLCI must be defined and
cannot be part of a PVC connection or management link. For multiplexed DLCIs, at least
one EDLCI must be unconnected for the DLCI to be a valid selection.
NOTES:
– Primary Destination DLCI has no value if Primary Destination Link contains no
value.
– For the basic FLEX feature set, only one EDLCI per multiplexed DLCI may be used
in the PVC connection.
16 – 1007 – Specifies the DLCI number.
Destination EDLCI
Possible Settings: 0 – 62
Default Setting: Initially blank; no default.
Specifies the destination Embedded Data Link Connection Identifier (EDLCI) for a frame
relay interface when a multiplexed DLCI record is selected as one end of a connection.
Display Conditions – This option only appears when the Primary Destination DLCI
contains a multiplexed DLCI record number.
0 – 62 – Specifies the EDLCI number.