Chapter 2 Periodic Inspection
3. Checking the Air Pump Nozzle Section
£WARNING
Mount the cover removed in place after checking. Failure to follow this instruction may result in a serious
injury.
When the wick tip in the air pump nozzle is not in the correct position, the proper amount of oil will not be supplied into
the pump causing the pump to seize.
Checking procedures - - - - - - - - - - - - - - - - - - - - - - - - - - - - - .
Checking
fmder
Correct
The wick tip
can be seen.
Incorrect
Incorrect
80
The wick tip cannot be seen.
Check that the wick tip can be seen from the checking finder (1) once a month. If the wick tip cannot be seen,
adjust the wick position.
Inoorreot~
Correct
Checking
Ventilator
~
(Note) The checking finder position can be moved by rotating the nozzle.
After checking the wick position, set the checking finder so that it
is facing you. In this position, the dust cannot enter the ventilator
easily.
(When moving the checking finder, the ventilator will move at the
same time because the checking finder and ventilator are at the
same position.)
Maintenance Edition - 23