Chapter 1 Operation Procedures
!Press
with pampeping
SolutiOd
Cdoling/Circi.Jiatiori
Device!
3. Water Section Preparation
1) Prepare the dampening solution cooling/circulation device.
(2)
(1)
Mix the alcohol in the dampening solution in
advance, and put it in the tank.
For the proper density of alcohol, please ask your
service technician when installing the press.
(Reference) To keep the proper dampening solution
level, 15 liters of dampening solution
should be prepared.
Remove the cap of the alcohol container and put
the alcohol in it.
(Note) When the alcohol is used up, bubbles will
appear in the tank easily. When the alcohol
is used up, immediately set the alcohol
density control dial (1) to "0" and supply the
alcohol in the alcohol container.
Set the power switch (1) at the ON position.
After running the device for from 15 minutes to 30
minutes and the dampening solution is properly
mixed and cooled, set the alcohol density control
dial (2) at the required density.
For the required density, please ask your service
technician when installing the press.
Put the hydrometer
(1)
in the hydrometer column,
then check the alcohol density.
Operation Edition - 7