Supplementary System Components - Siemens SIMODRIVE 611 Planning Manual

Drive converter
Hide thumbs Also See for SIMODRIVE 611:
Table of Contents

Advertisement

Supplementary System Components

8.1
Signal amplifier electronics
The signal amplifier electronics is used to amplify the current signals for distan-
ces > 18 m between the encoder and the digital drive module for 1FT6 motors
whereby the current signals are converted into voltage signals.
Notice
Current signals should no longer be used for new applications, as voltage
signals offer higher noise immunity.
The signal amplification electronics can only be used in conjunction with
the Performance control of SIMODRIVE 611 digital.
Table 8-1
Signal waveform
Input signal
Output signal
Signal frequency, max.
Operating voltage, max.
at remote sense
Operating current, max.
Encoder power supply
Encoder power supply current, max.
Dimensions (H x W x D)
Order number
Degree of protection of the enclosure
 Siemens AG 2001 All rights reserved
SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
Technical data of the signal amplifier electronics
Technical data
Sine–cosine
7 µA
1V
300 kHz
8 V DC
200 mA
5 V DC $ 5 %
120 mA
54 mm x 121 mm x 57 mm
6SN11 15–0AA12–0AA0
IP 65
to 16 µA
pp
pp
pp
8
8
8-217