6 Infeed Modules
6.6 DC link options
6.6.4
6
6-198
External pulsed resistors
Using the external pulsed resistors, the heat loss can be dissipated outside the
cabinet. External pulsed resistors are always required for the 28 kW UI module.
Shielded cables must be used to connect the pulsed resistors.
Notice
The pulsed resistor is equipped with a temperature monitoring function, which
protects it against overheating.
Table 6-17
External pulsed
resistor 0.3/25
kW
Order No.
6SN1113–
1AA00–0DA0
Integrated
in
Can be
UI module 28
used for
kW
Can be
used for
Pn
0.3 kW
P
25 kW
max
E
7.5 kWs
max
Degree of
IP 54
protection
Dimension drawings, refer to Section 13
UI modules with pulsed resistors
Pulsed resistors, technical data
External pulsed
resistor 1.5/25
kW
6SN1113–
1AA00–0CA0
–
–
UI module 28
kW
Pulsed resistor
–
module
6SN1113–
1AB0V–0BAV
1.5 kW
25 kW
180 kWs
IP20
SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
05.01
Internal pulsed
Internal pulsed
resistor 0.3/25
resistor 0.2/10
kW
kW
–
–
UI 10 kW,
UI 5 kW
pulsed resistor
module
–
–
–
–
0.3 kW
0.2 kW
25 kW
10 kW
7.5 kWs
13.5 kWs
refer to module
refer to module
Siemens AG 2001 All rights reserved