Select Terminal Functions - Siemens SIMODRIVE 611 Planning Manual

Drive converter
Hide thumbs Also See for SIMODRIVE 611:
Table of Contents

Advertisement

05.01
5.4 Main spindle control with analog setpoint interface 6SN1121–0BA1_–0AA_
5.4.1

Select terminal functions

The select input terminals E1 to E9 (max. 9) are freely–programmable. A control
parameter is assigned to each select terminal, in which the code number of the
selected function is entered.
Table 5-10
Select terminal functions
Select terminal
2nd torque limit value
Oscillation
Reset fault memory (reset) 1)
Open–loop torque controlled
operation 1)
Open–loop torque controlled
operation with slip monitoring
Star–delta operation
M19 operation
Ramp–time = 0
Integrator inhibit, speed
controller 1)
Gearbox stage (max. 3 terminals)
Setpoint enable
Positioning on
Position reference value 1–4
(max. 2 terminals)
Incremental positioning
Spindle re–synchronization
C axis
HPC axis 1)
Speed setpoint smoothing 1)
Suppress fault 11 1)
Inverter clock frequency
changeover 1)
_________
1)
Only these terminal functions are available in the HPC axis mode.
 Siemens AG 2001 All rights reserved
SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
When selected, if a speed, which can be parameterized, is exceeded, the 2nd
torque limit is activated when a speed, which is parameterized, is exceeded.
2 internal speed setpoints, where the frequency and speed can be adjusted, are
generated.
Acknowledges a fault/error message after the cause has been removed.
Note: Terminal 65 (controller enable) must be open.
The analog setpoint is interpreted as torque setpoint in this mode. (This function
is required for master–slave drives)
Open–loop torque controlled operation with slip monitoring
When the signal changes, the motor data sets are also changed and a change-
over made from the star to the delta winding configuration using control
commands. Note: This function can only be used for motors with star/delta
windings.
NC auxiliary function for oriented spindle stop. When selected, and if a speed,
which can be parameterized, is fallen below, a finer speed setpoint normalization
is selected.
If the enable voltage is connected to this terminal, the ramp–function generator
is bypassed.
The integral component of the PI speed controller is inhibited using this terminal.
A total of 8 parameter sets for setpoint normalization, speed monitoring, con-
troller setting, torque limiting and torque monitoring can be entered using these
terminals.
Terminal open–circuit: Digital zero setpoint
Terminal selected: The setpoint is enabled (analog setpoint or oscillation setpoint)
When selected, the internal closed–loop position control is selected and the
spindle is moved into the required position.
Using these terminals, a total of 4 parameterizable position reference values can
be entered.
When selected, the spindle moves from the actual position–controlled position
through a specified position difference.
The spindle is re–referenced: This is necessary after every mechanical gearbox
stage changeover.
Changeover to a finer C–axis setpoint normalization.
Note: Only setpoint input 2 (terminal 24–8) is evaluated.
Changeover to High Precision C axis mode; i.e. finer setpoint normalization and
higher speed control loop dynamic performance with a lower functional scope
(only E1 to E6 are evaluated).
Note: Only setpoint input 2 (terminal 24–8) is evaluated.
The speed setpoint smoothing is activated with a time constant, which can be
parameterized.
Fault message 11 is suppressed (speed controller at its limit) for the function
"travel to endstop".
It is possible to select different inverter clock frequencies using the select
terminals.
5 Control Modules
Function
5
5-115

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents