05.01
6.3.2
Technical data of the supplementary components
Cooling
components
Components
Component
Mounted fan for internal
6SN1162–
and external cooling
0BA02–
0AAV
Hose cooling package for
6SN1162–
an individual module com-
0BA03–0AAV
prising:
2x module connecting
flange, hose
2000 mm
1x cabinet connecting
flange
1x radial fan with cabinet
1)
connecting flange
(refer to Fig. 2-4)
Hose cooling package for
6SN1162–
2–tier configuration of I/R
0BA03–0CAV
55 kW and
PM 85 A comprising: 4x
module connecting flange,
hose
2000 mm
1x cabinet connecting
flange
1x radial fan with cabinet
1)
connecting flange
(refer to Fig. 2-4)
Motor protection circuit–
Size S00:
breaker
Setting value 0.3 A
Setting value 1 A
Quantity S0
Setting value 0.3 A
Setting value 1 A
Hot air deflection plate
6SN1162–
0BA01–0AA0
1)
Replacement filter element:
Warning
!
The fan may only be commissioned, if it is electrically connected with the mo-
dule housing (the PE of the fan is connected via the module housing).
Siemens AG 2001 All rights reserved
SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
Supply
Order No.
voltage
3–ph. 360 to
0.2 A to 0.3 A
510 VAC
45 to 65 Hz
3–ph. 360 to
1.0 A +20%
457 VAC
47.5 to
62.5 Hz
3–ph. 360 to
1.0 A +20%
457 VAC
47.5 to
62.5 Hz
3RV1011–0DA10 0.22–0.32 A
3RV1011–0KA10 0.9–1.25 A
3RV1021–0DA10 0.22–0.32 A
3RV1011–0KA10 0.9–1.25 A
Required for UI and pulsed–resistor modules when the pulsed resistor
is utilized to its maximum ( > 200 W ) (refer to Section 13, dimension
drawings)
Order No. 8MR 1191–0A0
Ordering location: Pfannenberg GmbH
Postfach 80747
21007 Hamburg
6 Infeed Modules
6.3 Technical data
Supply
Observe phase
current
sequence!
Direction of rota-
tion refer to the
arrow on the fan
Ccw direction of
rot. when viewing
the rotor
Ccw direction of
rot. when viewing
the rotor
Degr.
Weight
of pro-
[kg]
tection
IP 44
4
IP 54
8
IP 54
8
6-175
6