05.01
5.1 Feed control with user–friendly and analog setpoint interface 6SN1118–0AA11–0AA1
5.1.3
Option module, main spindle functions 6SN1114–0AA02–0AA0
Main spindle functions can also be realized using an option board (main spindle
drive option). In this case, the option board should be mounted on the control
board (this is only possible in conjunction with the user–friendly interface).
Installing the MSD
option
Fig. 5-2
Function overview
and settings on the
MSD option
Table 5-4
Function overview and settings on the MSD option
Parameter
Limit value stages
NC/NO
|I
| > I
term. 110/108
act
X
| n
| < n
term. 115/114
act
min
| n
| < n
term.216/214
act
X
n
= n
term. 127/126
set
set*
n < n
off
Ramp–function generator via
terminals 56/14
Tracking
Drift (main spindle drive ope-
ration)
Proportional gain
Integral action time
 Siemens AG 2001 All rights reserved
SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
Option board
Value range
The relay outputs of the limit value stages can
be defined as NC or NO contacts
4.5 %...100 %
0.3 %...1.7 % of n
max
3 %...100 % of n
max
n
difference< 20 mV
set
0.3 %...1.7 % of n
max
10 ms...1.1 s
0.1 s...11 s (changeover 1:10)
Active/inactive
–30 mV...+30 mV (referred to n
set
Reduce Kp to 0 %...95 %
Extend T
to 100 %...1500 %
N
5 Control Modules
X305
Mount on studs using M3x6 screws.
Tightening torque, 0.8 Nm.
Insert the front connector into the front panel,
insert the PC board in the locating lugs.
Establish the connection using X305.
Setting elements
0 Ω resistors
Pot. R211
Pot. R10
Pot. R43
Resistor R179
Pot. R1
Potentiometer R20
terminal 102
R270
)
Pot. R96
Pot. R45 + parameter board R25
Pot. R44 + parameter board R35