5.5 Induction Motor Control With Analog Setpoint Interface 6Sn1122-0Ba1_-0Aa - Siemens SIMODRIVE 611 Planning Manual

Drive converter
Hide thumbs Also See for SIMODRIVE 611:
Table of Contents

Advertisement

5 Control Modules
5.5 Induction motor control with analog setpoint interface 6SN1122–0BA1_–0AA_
5.5
6SN1122–0BA1_–0AA_
Induction motor
control
5
5-118
Induction motor control with analog setpoint interface
The following appropriate control components are available for standard
induction motors without rotary encoder (Order No. 6SN1122–0BA11–0AA1).
M3 / 0.8 Nm
0.8 Nm
Fig. 5-6
Induction motor control
Note
When using non–PELV circuits at terminals AS1, AS2, connector coding must
be used so that the connectors cannot be interchanged (refer to EN60204–1,
Section 6.4).
Order No. of the coding, refer to Catalog NC 60.
Notice
Only PELV circuits may be connected at connector X432 pin15 (FR–).
X2
X1
M
IR
56
91 A
14
M
24
92 A
8
M
663
289
65
11 A
81
21 A
31 A
E1
41 A
E2
E3
51 A
61 A
E4
E5
672
E6
673
E7
674
E8
E9
AS1
9
AS2
+
P
Version label
Software
M3 / 0.8 Nm
 Siemens AG 2001 All rights reserved