Shield Connecting Plates - Siemens SIMODRIVE 611 Planning Manual

Drive converter
Hide thumbs Also See for SIMODRIVE 611:
Table of Contents

Advertisement

10 Cabinet Design and EMC
10.1 Installation and connection regulations
Cabinet mounting panel
L1
L2 L3
Supply
10
1) Shield connection, connected through the largest possible surface area with the cabinet mounting panel.
2) Shield connection at the module–specific connecting panel
3) The PE cables can be alternatively connected via PE rail, taking into consideration EN50178
(protective connections).
4) Refer to Sections 3.4.2 and 3.1 for permissible commutating reactors for I/R module sinusoidal operation
Refer to Section 3.4.2 for permissible commutating reactors for the 28 kW UI module
A clearance of > 100mm around the HF reactor must be provided at the cable entry into the cabinet.
Fig. 10-1
10.1.1
10-308
Fuses
3
1)
1)
1)
1)
3
1)
PE
4
3) PE – rail is connected through a large surface area to the cabinet mounting panel
Connection diagram for line filters for 5 kW and 10 kW UI modules, for I/R modules, 16 kW to 120 kW.
The connection diagram is also valid for UE 28 kW, however, as a result of the uncontrolled infeed, 6–pulse
squarewave current is present

Shield connecting plates

Shield connecting plates, which can be retrofitted, are available for the infeed
modules and power modules. Mounting points are available on these plates to
attach terminals to connect a brake.
3
I/R module
or
U/I module
P600
1)
M600
U1
V1
1)
Reactor
3
1)
1)
4)
PE
SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
Encoder cables
Function
cables
MSD module
Feed drive
module
U2
V2
PE
U2
V2
1 W
PE
2 W
2 W
2)
2)
3
M
G
M
 Siemens AG 2001 All rights reserved
05.01
PE
2)
G