05.01
6.2
Power modules operated from an uncontrolled infeed
The drive modules can always be operated from the uncontrolled and controlled
infeed modules of the SIMODRIVE 611 drive converter system. The configuring/
engineering and power data of this Planning Guide refers to operation with the
controlled infeed/regenerative feedback modules. This data, if required, should
be corrected when operated from uncontrolled infeed modules.
– Operation of drive modules with PH and 1FE1 motors and induction motors
on the uncontrolled infeed
When operating main spindle and induction drive modules from uncontrolled
infeeds (UI modules), a lower maximum motor output is available in the upper
speed range than when using the infeed/regenerative feedback module.
For the UI module, the following inter–relationship is obtained for the available
continuous output as a result of the lower DC link voltage of 490 V (for line sup-
ply infeed with 3–ph. 400 V AC – 10%):
If
––––––––––––––––– < 1
then, the max. continuous output is given by:
P
Siemens AG 2001 All rights reserved
SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
6.2 Power modules operated from an uncontrolled infeed
V
DC link
1.5 x V
N motor
V
DC link
= P
x –––––––––––––––––––
cont.
N
1.5 x V
N motor
6 Infeed Modules
V
= 490 for UI modules
DC link
V
= 600 for I/R modules
DC link
6-169
6