5 Control Modules
5.3 Resolver control with standard and analog interface 6SN1118–0B_11–0AA0
5.3
6SN1118–0B_11–0AA0
Resolver control
with standard
interface
5
0.8 Nm
Fig. 5-4
5-110

Resolver control with standard and analog interface

For 1FK6 and 1FT6 motors with resolvers, a control module is available which
includes incremental shaft encoder interface with TTL signal output for external
processing. This is available as 1–axis and 2–axis versions. All of the axis–
specific settings are made on the control board.
1–axis version
M3 / 0.8 Nm
Drift
T
1
KP
TN
–X321–
56
14
24
20
75
15
16
96
9
22
9
663
AS1
AS2
–X331
M3 / 0.8 Nm
Resolver control with standard interface and analog interface
Note
When using non–PELV circuits at terminals AS1, AS2, connector coding must
be used so that the connectors cannot be interchanged (refer to EN60204–1,
Section 6.4).
Order No. of the coding, refer to Catalog NC 60.
0.8 Nm
9
65.1
15
258
–X332
Version label
SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
2–axis version
M3 / 0.8 Nm
Drift
1
T
kp
TN
Drift
T
2
KP
TN
–X321–X322
56
56
14
14
24
24
20
20
75
75
15
15
16
16
96
96
9
9
22
22
9
9
9
663
65.1
AS1
9
AS2
65.2
–X331
–X332
M3 / 0.8 Nm
 Siemens AG 2001 All rights reserved