Motor Changeover, Individual Induction Motors 611 Analog - Siemens SIMODRIVE 611 Planning Manual

Drive converter
Hide thumbs Also See for SIMODRIVE 611:
Table of Contents

Advertisement

05.01
9.11.2

Motor changeover, individual induction motors 611 analog

The SIMODRIVE 611 IM module allows up to four different motors to be chan-
ged over. Each motor has a dedicated motor parameter set.
K1
K2
Pulse enable
K3
K4
Select terminal input
0
1
1st input
2nd input
0
0
Motor selection
1
2
K1
K
1H
M1
3 ~
K
2
Motor 1
K
3
K
4
1)
Several motors cannot be simultaneously controlled as this interlocked in the software.
In addition, the recommended contactor interlocking ensures that only one motor
can be operated.
2)
Only required for high–speed special motors.
Fig. 9-30
Motor changeover at the SIMODRIVE 611 IM module
For motor changeover, an auxiliary contactor 3RH11 and a main contactor
3RT10 are required for each motor.
A binary–coded switching command is connected to select input terminals
En/En + 1 (max. two terminals for four motors) to changeover a motor. The
changeover command is only executed when the drive pulses are inhibited. In
this case, one of the terminals 663, 65 or 81 (function: Pulse inhibit) must be
opened. After the pulses have been inhibited, the active motor parameter set is
loaded and the motor auxiliary contactors controlled via select relay.
 Siemens AG 2001 All rights reserved
SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
9.11 Induction motor operation 611A (611D/611U)
SIMODRIVE
611 IM
T.663
P24
En
0
1
En + 1
1
1
3
4
U2 2 W V2
K2
K
PTC
PTC
2H
M2
3 ~
K
1
Motor 2
K
3
K
4
9 Important Circuit Information
Output terminals
Aw11)
Ax1
Ay1
Az1
K
K
1H
2H
2)
K3
K4
K
K
3H
4H
PTC
M3
3 ~
K
1
Motor 3
K
2
K
4
K
K
3H
4H
0 V
PTC
M4
3 ~
K
1
Motor 4
K
2
K
3
9-291