Technical Data Of The Supplementary Components - Siemens SIMODRIVE 611 digital Configuration Manual

Drive converters
Hide thumbs Also See for SIMODRIVE 611 digital:
Table of Contents

Advertisement

Aotewell Ltd
05.01
10.04
11.05
6.3.3
Cooling
components
Components
Built–on fan for internal and ex-
ternal cooling
Hose cooling package 1 for an
individual module comprising:
S
2x module connection
flange, 2000 mm hose
S
1x cabinet connection flange
S
1x radial fan with cabinet
connection flange
(refer to Fig. 2-7)
Hose cooling package 2 for a
2–tier configuration of
I/R 55 kW and LT 200 A:
S
4x module connection
flange, 2000 mm hose
S
1x cabinet connection flange
S
1x radial fan with cabinet
connection flange
(refer to Fig. 2-7)
Motor circuit–breaker
Air baffle plate
width 100 mm
1)
Replacement filter element:
© Siemens AG 2008 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 05/2008 Edition
HongKong|UK|China
www.aotewell.com

Technical data of the supplementary components

Order
number
6SN11 62–
0BA02–0AAV
6SN11 62–
0BA03–0AA1
1)
6SN11 62–
0BA03–0CA1
1)
Size S00:
Setting value, 0.3 A
Setting value, 1 A
Size S0
Setting value, 0.3 A
Setting value, 1 A
6SN1162–
0BA01–0AA0
Order No. AFF0
Can be ordered from: Pfannenberg GmbH
Postfach 80747
D–21007 Hamburg
Warning
!
The fan may only be commissioned if it is electrically connected to the module
housing (PE fan via module housing).
Caution
!
If the fan has the incorrect direction of rotation (refer to the arrow on the fan)
then cooling is not guaranteed!
sales@aotewell.com
Supply
Supply
voltage
current
3–ph.
0.2...0.3 A
360..510 V
AC
45...65 Hz
3–ph.
1.0...1.2 A
360..457 V
AC
47.5...62.5 Hz
3–ph.
1.0...1.2 A
360..457 V
AC
47.5...62.5 Hz
3RV1011–0DA10 0.22–0.32 A
3RV1011–0KA10 0.9–1.25 A
3RV1021–0DA10 0.22–0.32 A
3RV1011–0KA10 0.9–1.25 A
If heat sensitive parts are located above the UI and/or PR module
with a clearance < 500 mm, e.g. cable ducts, then an air baffle plate
must be used
(refer to Chapter 12, Dimension drawings).
Industry Automation
6 Infeed Modules
6.3 Technical data
Observe
Degree
Weight
the rotating
of
[kg]
field!
protec-
tion
For the di-
IP 44
4
rection of
rotation, re-
fer to the di-
rection of
the arrow
on the fan
Counter–
IP 54
8
clockwise
direction of
rotation
when view-
ing the
rotor
Counter–
IP 54
8
clockwise
direction of
rotation
when view-
ing the
rotor
6-165
+86-755-8660-6182
6

Hide quick links:

Advertisement

Table of Contents
loading