Mode Of Operation - Siemens SIMODRIVE 611 Planning Manual

Drive converter
Hide thumbs Also See for SIMODRIVE 611:
Table of Contents

Advertisement

6 Infeed Modules
6.5 Monitoring module
6.5.2
6
Fig. 6-9
6-184

Mode of operation

Parameters critical for operation are monitored in the monitoring module, for
example:
S
DC link voltage
S
Controller power supply (15 V)
S
5 V voltage level
If these parameters are in the permissible operating range, then the internal
prerequisites are provided for the "equipment ready" signal. The group of modu-
les is enabled at the monitoring module as soon as the external enable signals
have been made available via terminals 63 (pulse enable) and 64 (drive ena-
ble). The sum signal controls the "ready" relay and can be taken, floating, via
terminals 72/73.2 and 73.1/74. The load capability of the contacts is 250 V AC/1
A or 30 V DC/1 A.
The signal statuses of the monitoring circuits are displayed using LEDs on the
front panel of the monitoring module
Electronics power
supply faulted
Equipment not ready,
external enable signals
missing
Free
LED display of the monitoring module
LED display
5 V voltage
Red
red
level faulted
Equipment ready
green
Yellow
(DC link
pre–charged)
red
Overvoltage,
Red
DC link
 Siemens AG 2001 All rights reserved